{"id":83750,"date":"2026-07-31T11:45:59","date_gmt":"2026-07-31T16:45:59","guid":{"rendered":"https:\/\/elicromperu.com\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/"},"modified":"2026-07-31T12:02:52","modified_gmt":"2026-07-31T17:02:52","slug":"calibracion-termohigrometros-lima-peru-alcance-acreditado","status":"publish","type":"post","link":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/","title":{"rendered":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa"},"content":{"rendered":"<div class=\"elicrom-article\"><style>\r\n.elicrom-article{color:#1a1a1a;font-size:16px;line-height:1.7;font-family:inherit;max-width:100%;overflow-wrap:anywhere;word-wrap:break-word;-webkit-text-size-adjust:100%;text-size-adjust:100%}\r\n.elicrom-article p{text-align:left;margin:0 0 16px;hyphens:auto}\r\n.elicrom-article h2.elicrom-h2{color:#0a2540;font-size:clamp(1.25rem,4.6vw,1.7rem);font-weight:700;margin:32px 0 14px;padding-bottom:8px;border-bottom:3px solid #06b6d4;line-height:1.3}\r\n.elicrom-article .elicrom-box{background:#f0f9ff;border-left:4px solid #06b6d4;border-radius:0 10px 10px 0;padding:14px 14px;margin:0 0 20px}\r\n.elicrom-article .elicrom-box-ok{background:#ecfdf5;border-left:4px solid #059669;border-radius:0 10px 10px 0;padding:14px 14px;margin:0 0 20px}\r\n.elicrom-article .elicrom-toc{background:#f7fafc;border:1px solid #b4c0cd;border-radius:12px;padding:16px 14px;margin:0 0 24px}\r\n.elicrom-article .elicrom-toc ol{margin:0;padding-left:18px;line-height:1.75}\r\n.elicrom-article .elicrom-toc a{color:#0891b2;text-decoration:underline}\r\n.elicrom-article .elicrom-table-wrap{width:100%;max-width:100%;overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 18px;border-radius:10px;border:1px solid #d7e0ea;background:#fff;box-shadow:inset 0 -1px 0 rgba(10,37,64,.04)}\r\n.elicrom-article .elicrom-table-wrap::before{content:\"Desliza horizontalmente \\2192\";display:block;font-size:12px;color:#64748b;padding:8px 12px 0;font-style:italic}\r\n.elicrom-article .elicrom-table-wrap table{width:100%;min-width:520px;border-collapse:collapse;margin:0;font-size:14px}\r\n.elicrom-article .elicrom-table-wrap table.elicrom-table-sm{min-width:0}\r\n.elicrom-article .elicrom-table-wrap th{background:#0a2540;color:#fff;text-align:left;padding:10px 12px;font-weight:600}\r\n.elicrom-article .elicrom-table-wrap td{padding:10px 12px;border-bottom:1px solid #b4c0cd;vertical-align:top}\r\n.elicrom-article .elicrom-img{text-align:center;margin:24px 0}\r\n.elicrom-article .elicrom-img img{display:block;width:100%;max-width:min(100%,480px);height:auto;margin:0 auto;border-radius:12px;box-shadow:0 3px 14px rgba(10,37,64,.10)}\r\n.elicrom-article .elicrom-img figcaption,.elicrom-article .elicrom-img span{font-size:13px;color:#5f6b76;font-style:italic;display:inline-block;margin-top:8px;padding:0 8px;line-height:1.4}\r\n.elicrom-article .elicrom-cta-final{background:linear-gradient(135deg,#0a2540,#0891b2);border-radius:14px;padding:22px 16px;text-align:center;margin:28px 0 0}\r\n.elicrom-article .elicrom-cta-final h2{color:#fff!important;border:none!important;margin:0 0 10px!important;padding:0!important;font-size:clamp(1.2rem,4.8vw,1.55rem)!important;font-weight:700;line-height:1.3}\r\n.elicrom-article .elicrom-cta-final p{color:#dbeafe;text-align:center;margin:0 0 18px;font-size:15px;line-height:1.55}\r\n.elicrom-article .elicrom-cta-btn{display:inline-block;background:#fff;color:#0a2540;padding:14px 22px;border-radius:10px;font-weight:700;text-decoration:none;margin:4px;min-height:44px;line-height:1.2;box-sizing:border-box}\r\n.elicrom-faq{margin:0 0 24px;border:1px solid #b4c0cd;border-radius:12px;overflow:hidden;background:#fff}\r\n.elicrom-faq details{border-bottom:1px solid #b4c0cd}\r\n.elicrom-faq details:last-child{border-bottom:none}\r\n.elicrom-faq summary{list-style:none;cursor:pointer;padding:16px 48px 16px 14px;position:relative;color:#0a2540;font-weight:600;font-size:15px;line-height:1.45;background:#f7fafc;min-height:48px;box-sizing:border-box}\r\n.elicrom-faq summary::-webkit-details-marker{display:none}\r\n.elicrom-faq summary::after{content:\"+\";position:absolute;right:14px;top:50%;transform:translateY(-50%);color:#0891b2;font-size:22px;font-weight:700;line-height:1}\r\n.elicrom-faq details[open] summary{background:#eaf4f9;border-bottom:1px solid #dbe7f0}\r\n.elicrom-faq details[open] summary::after{content:\"\u2013\"}\r\n.elicrom-faq .faq-a{margin:0;padding:12px 14px 16px;color:#1a1a1a;font-size:15px;line-height:1.55}\r\n.elicrom-faq .faq-a a{color:#0891b2;font-weight:600;text-decoration:underline}\r\n@media (min-width:768px){\r\n  .elicrom-article{font-size:17px;line-height:1.8}\r\n  .elicrom-article p{text-align:justify}\r\n  .elicrom-article .elicrom-table-wrap::before{display:none}\r\n  .elicrom-article .elicrom-table-wrap table{min-width:0;font-size:15px}\r\n  .elicrom-article .elicrom-table-wrap th,.elicrom-article .elicrom-table-wrap td{padding:12px 14px}\r\n  .elicrom-article .elicrom-cta-final{padding:34px}\r\n  .elicrom-faq summary{font-size:16px;padding:14px 48px 14px 16px}\r\n}\r\n@media (max-width:480px){\r\n  .elicrom-article .elicrom-toc{padding:14px 12px}\r\n  .elicrom-article .elicrom-box,.elicrom-article .elicrom-box-ok{padding:12px;border-left-width:3px}\r\n  .elicrom-article .elicrom-table-wrap table{font-size:13px}\r\n  .elicrom-article .elicrom-table-wrap th,.elicrom-article .elicrom-table-wrap td{padding:8px 10px}\r\n  .elicrom-faq summary{font-size:14.5px}\r\n  .elicrom-article .elicrom-cta-btn{display:block;width:100%;max-width:320px;margin:8px auto;padding:15px 18px}\r\n}\r\n<\/style>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 18px\"><strong style=\"color:#0a2540\">Calibraci\u00f3n de termohigr\u00f3metros<\/strong> en Lima: si su instrumento de humedad y temperatura no tiene certificado trazable, arriesga hallazgos en auditor\u00edas farmac\u00e9uticas, HVAC y salud ocupacional. <strong style=\"color:#0a2540\">ELICROM Per\u00fa<\/strong> \u2014laboratorio con acreditaci\u00f3n <strong>ISO\/IEC 17025<\/strong> en Lima\u2014 calibra <strong style=\"color:#0a2540\">termohigr\u00f3metros port\u00e1tiles<\/strong> y <strong style=\"color:#0a2540\">medidores WBGT<\/strong> en c\u00e1mara clim\u00e1tica, con rangos y CMC del alcance acreditado vigente (actualizado 09 de enero de 2026).<\/p>\r\n\r\n<div class=\"elicrom-box\" style=\"margin:0 0 24px\">\r\n<p style=\"margin:0 0 8px;color:#0a2540;font-weight:700\">En esta gu\u00eda encontrar\u00e1<\/p>\r\n<ul style=\"margin:0;padding-left:20px;color:#1a1a1a\">\r\n<li>Qu\u00e9 es la calibraci\u00f3n de termohigr\u00f3metros y medidores WBGT<\/li>\r\n<li>Beneficios, riesgos e industrias donde aplica<\/li>\r\n<li>Metodolog\u00eda, alcance acreditado (CMC) y caso pr\u00e1ctico<\/li>\r\n<li>Preguntas frecuentes para cotizar con claridad<\/li>\r\n<\/ul>\r\n<\/div>\r\n\r\n<nav aria-label=\"Tabla de contenidos\" class=\"elicrom-toc\">\r\n<p style=\"margin:0 0 12px;color:#0a2540;font-weight:700;font-size:clamp(1rem,4vw,1.125rem)\">Tabla de contenidos<\/p>\r\n<ol style=\"margin:0;padding-left:22px;color:#1a1a1a;line-height:1.7\">\r\n<li><a href=\"#que-es\" style=\"color:#0891b2\">Qu\u00e9 es la calibraci\u00f3n de termohigr\u00f3metros<\/a><\/li>\r\n<li><a href=\"#instrumentos\" style=\"color:#0891b2\">Instrumentos cubiertos vs dataloggers<\/a><\/li>\r\n<li><a href=\"#beneficios-riesgos\" style=\"color:#0891b2\">Beneficios y riesgos<\/a><\/li>\r\n<li><a href=\"#industrias\" style=\"color:#0891b2\">Industrias donde aplica<\/a><\/li>\r\n<li><a href=\"#normativa\" style=\"color:#0891b2\">Normativa aplicable<\/a><\/li>\r\n<li><a href=\"#metodologia\" style=\"color:#0891b2\">C\u00f3mo calibra ELICROM<\/a><\/li>\r\n<li><a href=\"#alcance-acreditado\" style=\"color:#0891b2\">Alcance acreditado (CMC Lima)<\/a><\/li>\r\n<li><a href=\"#caso-practico\" style=\"color:#0891b2\">Caso pr\u00e1ctico<\/a><\/li>\r\n<li><a href=\"#faq\" style=\"color:#0891b2\">Preguntas frecuentes<\/a><\/li>\r\n<\/ol>\r\n<\/nav>\r\n\r\n<!-- Imagen destacada del post (no repetir aqu\u00ed): tecnico-elicrom-calibrando-termohigrometro-ar.png -->\r\n\r\n<h2 id=\"que-es\" class=\"elicrom-h2\">Qu\u00e9 es la calibraci\u00f3n de termohigr\u00f3metros<\/h2>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 16px\">Seg\u00fan el VIM (JCGM 200:2012), calibrar un <strong style=\"color:#0a2540\">termohigr\u00f3metro<\/strong> significa <strong>cuantificar el error<\/strong> con el que el equipo indica la <strong>humedad relativa<\/strong> y\/o la <strong>temperatura<\/strong> en los puntos acordados, por comparaci\u00f3n con un termohigr\u00f3metro patr\u00f3n en c\u00e1mara clim\u00e1tica estabilizada.<\/p>\r\n\r\n<div class=\"elicrom-box-ok\" style=\"margin:0 0 22px\">\r\n<p style=\"margin:0;color:#1a1a1a\"><strong style=\"color:#065f46\">Respuesta directa:<\/strong> el certificado documenta errores e incertidumbres (GUM, k = 2) para %HR y \u00b0C, con trazabilidad al SI. En medidores <strong>WBGT<\/strong> se verifican adem\u00e1s bulbo h\u00famedo, bulbo seco, temperatura de globo y punto de roc\u00edo seg\u00fan el alcance publicado.<\/p>\r\n<\/div>\r\n\r\n<div class=\"elicrom-box\" style=\"margin:0 0 22px\">\r\n<p style=\"margin:0;color:#1a1a1a\"><strong style=\"color:#0a2540\">Definici\u00f3n operativa ELICROM Per\u00fa:<\/strong> calibraci\u00f3n de termohigr\u00f3metro = determinaci\u00f3n documentada del error de indicaci\u00f3n de %HR y\/o temperatura en los puntos acordados, con incertidumbre expandida seg\u00fan GUM (k = 2), por comparaci\u00f3n con termohigr\u00f3metro patr\u00f3n en c\u00e1mara clim\u00e1tica y trazabilidad al SI.<\/p>\r\n<\/div>\r\n\r\n<h2 id=\"instrumentos\" class=\"elicrom-h2\">Instrumentos cubiertos vs dataloggers<\/h2>\r\n\r\n<div class=\"elicrom-table-wrap\"><table><thead><tr>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Instrumento<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Magnitudes<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Enfoque de esta gu\u00eda<\/th>\r\n<\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;font-weight:600\">Termohigr\u00f3metro port\u00e1til<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">%HR, \u00b0C<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#065f46\">S\u00ed \u2014 foco principal<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;font-weight:600\">Medidor WBGT<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Bulbo h\u00famedo\/seco, globo, punto de roc\u00edo<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#065f46\">S\u00ed \u2014 misma matriz CMC<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;font-weight:600\">Datalogger T\/%HR<\/td><td style=\"padding:12px 14px\">%HR, \u00b0C (registro continuo)<\/td><td style=\"padding:12px 14px\">Gu\u00eda dedicada: <a href=\"https:\/\/elicromperu.com\/calibracion-dataloggers-temperatura-humedad-lima-peru-alcance-acreditado\/\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">calibraci\u00f3n de dataloggers<\/a><\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<p style=\"color:#475569;margin:0 0 22px;font-size:15px\"><em>Nota Lima:<\/em> termohigr\u00f3metros y dataloggers comparten la misma matriz acreditada de humedad\/temperatura. Esta p\u00e1gina se centra en port\u00e1tiles y WBGT; para registradores de cadena de fr\u00edo consulte la gu\u00eda de dataloggers. El alcance acreditado de Lima cubre <strong>\u221220 a 60 \u00b0C<\/strong> y <strong>10\u201390 %HR<\/strong>. Para otros rangos o equipos especiales, ind\u00edquelo al cotizar.<\/p>\r\n\r\n<div class=\"elicrom-box\" style=\"margin:0 0 26px\"><p style=\"margin:0;color:#1a1a1a\">\u00bfNecesita calibrar un termohigr\u00f3metro o un datalogger? <a href=\"https:\/\/elicromperu.com\/\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">ELICROM Per\u00fa<\/a> \u00b7 <a href=\"https:\/\/servicio.elicrom.com\/servicio.cliente\/php\/cotizacion\/index.php?_gl=1*tk5fep*_gcl_au*MTgxMTYxOTQ3NC4xNzc5MjE3NTkz*_ga*OTUyODM1NjgxLjE3NTQzMTk1MDM.*_ga_N56ERV2D97*czE3ODQ1NjYxNTUkbzMxMSRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.*_ga_PX1553NKMT*czE3ODQ1NjYxNTUkbzMwNyRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">Solicitar Presupuesto<\/a>.<\/p><\/div>\r\n\r\n<h2 id=\"beneficios-riesgos\" class=\"elicrom-h2\">Beneficios de calibrar y riesgos de no hacerlo<\/h2>\r\n\r\n<div class=\"elicrom-table-wrap\"><table class=\"elicrom-table-sm\"><thead><tr>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Beneficios<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Riesgos de no calibrar<\/th>\r\n<\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Evidencia trazable ISO\/IEC 17025 para auditor\u00edas<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Hallazgos en calidad \/ salud ocupacional<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Correcciones aplicables a lecturas de %HR y \u00b0C<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Decisiones err\u00f3neas de almacenamiento o HVAC<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Confianza en mediciones WBGT de estr\u00e9s t\u00e9rmico<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Subestimar o sobrestimar riesgo t\u00e9rmico laboral<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;background:#f7fafc\">Base para intervalos de recalibraci\u00f3n del usuario<\/td><td style=\"padding:12px 14px;background:#f7fafc\">Costos mayores por no conformidades<\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<h2 id=\"industrias\" class=\"elicrom-h2\">Industrias y usos t\u00edpicos en Per\u00fa<\/h2>\r\n\r\n<div class=\"elicrom-table-wrap\"><table class=\"elicrom-table-sm\"><thead><tr>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Sector<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Uso t\u00edpico<\/th>\r\n<\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Farmac\u00e9utico \/ dispositivos<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Almacenes, c\u00e1maras y monitoreo ambiental<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">HVAC \/ laboratorios<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Verificaci\u00f3n de condiciones de salas y equipos<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Salud ocupacional \/ miner\u00eda \/ construcci\u00f3n<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Medidores WBGT de estr\u00e9s t\u00e9rmico por calor<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;background:#f7fafc\">Museos \/ archivo<\/td><td style=\"padding:12px 14px;background:#f7fafc\">Control de humedad relativa en conservaci\u00f3n<\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 22px\">Relacionado: <a href=\"https:\/\/elicromperu.com\/calibracion-dataloggers-temperatura-humedad-lima-peru-alcance-acreditado\/\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">dataloggers<\/a> \u00b7 <a href=\"https:\/\/elicromperu.com\/calibracion-termometros-lima-peru-alcance-acreditado\/\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">term\u00f3metros<\/a> \u00b7 <a href=\"https:\/\/elicromperu.com\/calibracion-medios-isotermos-lima-peru-alcance-acreditado\/\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">medios isotermos<\/a>.<\/p>\r\n\r\n<h2 id=\"normativa\" class=\"elicrom-h2\">Normativa aplicable y referencias t\u00e9cnicas<\/h2>\r\n\r\n<div class=\"elicrom-table-wrap\"><table class=\"elicrom-table-sm\"><thead><tr><th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Norma \/ Documento<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Aplicaci\u00f3n<\/th><\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">ISO\/IEC 17025:2017<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Competencia de laboratorios de calibraci\u00f3n acreditados<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">ISO 7726<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Ergonom\u00eda del ambiente t\u00e9rmico \u2014 instrumentos de medici\u00f3n<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">ISO 7243 (WBGT)<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Evaluaci\u00f3n del estr\u00e9s t\u00e9rmico por calor<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;background:#f7fafc\">JCGM 100:2008 (GUM)<\/td><td style=\"padding:12px 14px;background:#f7fafc\">Evaluaci\u00f3n y expresi\u00f3n de la incertidumbre de medici\u00f3n<\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<h2 id=\"metodologia\" class=\"elicrom-h2\">C\u00f3mo realiza ELICROM Per\u00fa la calibraci\u00f3n<\/h2>\r\n\r\n<div class=\"elicrom-table-wrap\"><table class=\"elicrom-table-sm\"><thead><tr>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Etapa<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Qu\u00e9 se hace<\/th>\r\n<\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;font-weight:600\">1. Alcance<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Confirmaci\u00f3n de puntos de %HR y \u00b0C (y canales WBGT si aplica)<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;font-weight:600\">2. Estabilizaci\u00f3n<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">C\u00e1mara clim\u00e1tica en cada punto acordado<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;font-weight:600\">3. Comparaci\u00f3n<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Registro simult\u00e1neo del patr\u00f3n y del instrumento bajo prueba<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;font-weight:600\">4. C\u00e1lculo<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">Error e incertidumbre expandida seg\u00fan GUM (k = 2)<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;font-weight:600\">5. Certificado<\/td><td style=\"padding:12px 14px\">Informe con trazabilidad al SI y condiciones de calibraci\u00f3n<\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 16px\">Procedimiento t\u00edpico: <strong style=\"color:#0a2540\">PEC.EL.HT<\/strong> \u00b7 comparaci\u00f3n directa frente a patr\u00f3n de referencia. Los certificados emitidos en Lima siguen el formato de la red ELICROM.<\/p>\r\n\r\n<div class=\"elicrom-img\"><img decoding=\"async\" src=\"https:\/\/elicromperu.com\/wp-content\/uploads\/2026\/07\/termohigrometro-datalogger-ar.png\" alt=\"Termohigr\u00f3metros y medidores de humedad-temperatura calibrados en Lima Per\u00fa\" loading=\"lazy\"  \/><span>Termohigr\u00f3metros port\u00e1tiles y medidores WBGT \u2014 calibraci\u00f3n en ELICROM Per\u00fa (Lima)<\/span><\/div>\r\n\r\n<h2 id=\"alcance-acreditado\" class=\"elicrom-h2\">Alcance acreditado ISO\/IEC 17025 \u2014 Lima<\/h2>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 16px\">Tabla del alcance acreditado para <strong style=\"color:#0a2540\">humedad relativa y temperatura<\/strong> del laboratorio de Lima (9 filas de CMC: 4 de %HR y 5 de \u00b0C, actualizado 09 de enero de 2026). Aplica a termohigr\u00f3metros port\u00e1tiles y medidores WBGT dentro de los rangos publicados.<\/p>\r\n\r\n<div class=\"elicrom-table-wrap\"><table style=\"width:100%;border-collapse:collapse;font-size:14px;min-width:520px\"><thead><tr><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Instrumento<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Magnitudes<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Uso t\u00edpico en Per\u00fa<\/th><\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\"><strong>Termohigr\u00f3metro port\u00e1til<\/strong><\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">%HR, \u00b0C<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">Almacenes farmac\u00e9uticos, c\u00e1maras fr\u00edas, HVAC, museos<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\"><strong>Datalogger<\/strong><\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">%HR, \u00b0C (registro continuo)<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">Cadena de fr\u00edo, validaci\u00f3n de cuartos, monitoreo MAP<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;color:#1a1a1a\"><strong>Medidor WBGT<\/strong><\/td><td style=\"padding:12px 14px;color:#1a1a1a\">Bulbo h\u00famedo\/seco, globo, punto de roc\u00edo<\/td><td style=\"padding:12px 14px;color:#1a1a1a\">Salud ocupacional, miner\u00eda, construcci\u00f3n, industria<\/td><\/tr>\r\n<\/tbody><\/table>\r\n\r\n<p style=\"text-align:justify;color:#1a1a1a;margin:0 0 22px;font-size:15px;color:#475569\"><em>Nota Lima:<\/em> analizadores de humedad de muestra (% h), temperaturas fuera de <strong>&minus;10 a 60 \u00b0C<\/strong>, humedad fuera de <strong>10\u201390 %HR<\/strong> y c\u00e1maras clim\u00e1ticas completas como unidad <strong>no figuran<\/strong> en la matriz publicada para Lima a abril de 2026. En Guayaquil (Ecuador) el alcance de humedad\/temperatura puede ser m\u00e1s amplio; no reutilice esas CMC para certificados CTM-XXXX emitidos en Per\u00fa.<\/p>\r\n\r\n<h2 style=\"color:#0a2540;font-size:31px;font-weight:700;margin:42px 0 16px;padding-bottom:10px;border-bottom:3px solid #06b6d4;line-height:1.25\">Marco normativo aplicable<\/h2>\r\n\r\n<table style=\"width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px\"><thead><tr><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Norma \/ Documento<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Aplicaci\u00f3n<\/th><\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">ISO\/IEC 17025:2017<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">Competencia de laboratorios de calibraci\u00f3n acreditados<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">ISO 7726<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">Ergonom\u00eda del ambiente t\u00e9rmico \u2014 instrumentos de medici\u00f3n<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">ISO 7243 (WBGT)<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;color:#1a1a1a\">Evaluaci\u00f3n del estr\u00e9s t\u00e9rmico por calor<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;background:#f7fafc;color:#1a1a1a\">JCGM 100:2008 (GUM)<\/td><td style=\"padding:12px 14px;background:#f7fafc;color:#1a1a1a\">Evaluaci\u00f3n y expresi\u00f3n de la incertidumbre de medici\u00f3n<\/td><\/tr>\r\n<\/tbody><\/table>\r\n\r\n<h2 style=\"color:#0a2540;font-size:31px;font-weight:700;margin:42px 0 16px;padding-bottom:10px;border-bottom:3px solid #06b6d4;line-height:1.25\">Metodolog\u00eda de calibraci\u00f3n en ELICROM Per\u00fa<\/h2>\r\n\r\n<p style=\"text-align:justify;color:#1a1a1a;margin:0 0 22px\">ELICROM Per\u00fa aplica comparaci\u00f3n directa en c\u00e1mara clim\u00e1tica: estabilizaci\u00f3n de temperatura y humedad en puntos acordados; registro simult\u00e1neo del patr\u00f3n y del instrumento bajo prueba; c\u00e1lculo de error e incertidumbre seg\u00fan GUM para cada magnitud calibrada. En medidores WBGT se incluyen los canales de bulbo h\u00famedo, bulbo seco, temperatura de globo y punto de roc\u00edo seg\u00fan el alcance. Los certificados emitidos en Lima llevan prefijo de certificado ELICROM (mismo formato que la red).<\/p>\r\n\r\n<div style=\"text-align:center;margin:30px 0\"><img decoding=\"async\" src=\"https:\/\/elicromperu.com\/wp-content\/uploads\/2026\/07\/termohigrometro-datalogger-ar.png\" alt=\"Termohigr\u00f3metros y dataloggers calibrados en Lima Per\u00fa\" style=\"max-width:520px;width:100%;height:auto;border-radius:12px;box-shadow:0 3px 14px rgba(10,37,64,0.10)\" \/><br \/><span style=\"font-size:13px;color:#5f6b76;font-style:italic;display:inline-block;margin-top:8px\">Termohigr\u00f3metros, dataloggers y medidores WBGT \u2014 calibraci\u00f3n en ELICROM Per\u00fa (Lima).<\/span><\/div>\r\n\r\n<h2 style=\"color:#0a2540;font-size:31px;font-weight:700;margin:42px 0 16px;padding-bottom:10px;border-bottom:3px solid #06b6d4;line-height:1.25\">Alcance acreditado ISO\/IEC 17025 \u2014 Lima (Per\u00fa)<\/h2>\r\n\r\n<p style=\"text-align:justify;color:#1a1a1a;margin:0 0 22px\">Tabla del alcance acreditado para <strong style=\"color:#0a2540\">humedad relativa y temperatura<\/strong> del laboratorio de Lima (8 filas de CMC: 4 de %HR y 4 de \u00b0C, actualizado 09 de enero de 2026).<\/p>\r\n\r\n<table style=\"width:100%;border-collapse:collapse;margin:0 0 26px;font-size:15px\"><thead><tr><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Equipos cubiertos<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Acreditaci\u00f3n<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Par\u00e1metro<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Rango<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">CMC<\/th><th style=\"background:#0a2540;color:#fff;text-align:left;padding:12px 14px;font-weight:600\">Comentarios<\/th><\/tr><\/thead><tbody>\n<tr><td rowspan=9 style=\"padding:12px;border:1px solid #8fa1b5;vertical-align:top;background:#f8fafc;color:#1a1a1a;line-height:1.7\">&bull; Termohigr&oacute;metros<br>&bull; Medidores WBGT<\/td><td rowspan=9 style=\"padding:12px;border:1px solid #8fa1b5;vertical-align:top;background:#ecfdf5;color:#065f46;font-weight:600\">Calibraci&oacute;n Acreditada ISO\/IEC 17025<\/td><td rowspan=4 style=\"padding:12px;border:1px solid #8fa1b5;vertical-align:top;background:#eff6ff;color:#1a1a1a;font-weight:600\">Humedad relativa<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">(10 a 30)  %HR<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">0,86  %HR<\/td><td rowspan=9 style=\"padding:12px;border:1px solid #8fa1b5;vertical-align:top;color:#1a1a1a\">Termohigr&oacute;metro patr&oacute;n y c&aacute;mara clim&aacute;tica<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">(30 a 50)  %HR<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">0,86  %HR<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">(50 a 70)  %HR<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">0,81  %HR<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">(70 a 90)  %HR<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">0,98  %HR<\/td><\/tr>\r\n<tr><td rowspan=5 style=\"padding:12px;border:1px solid #8fa1b5;vertical-align:top;background:#eff6ff;color:#1a1a1a;font-weight:600\">Temperatura<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">(-20 a 0) &deg;C<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">0,44 &deg;C<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">(0 a 20) &deg;C<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">0,19 &deg;C<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">(20 a 30) &deg;C<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">0,16 &deg;C<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">(30 a 40) &deg;C<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;background:#f7fafc;color:#1a1a1a\">0,13 &deg;C<\/td><\/tr>\r\n<tr><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">(40 a 60) &deg;C<\/td><td style=\"padding:10px 12px;border:1px solid #b4c0cd;color:#1a1a1a\">0,11 &deg;C<\/td><\/tr>\n<\/tbody><\/table><\/div>\r\n\r\n<p style=\"color:#475569;margin:0 0 22px;font-size:15px\"><em>Diferencias CMC Lima vs. otras sedes:<\/em> Lima publica humedad de <strong>10 a 90 %HR<\/strong> y temperatura de <strong>\u221220 a 60 \u00b0C<\/strong>. Use siempre la CMC de la sede emisora del certificado.<\/p>\r\n\r\n<div class=\"elicrom-box\" style=\"margin:0 0 26px\"><p style=\"margin:0;color:#1a1a1a\">\u00bfListo para calibrar su termohigr\u00f3metro en Per\u00fa? <a href=\"https:\/\/servicio.elicrom.com\/servicio.cliente\/php\/cotizacion\/index.php?_gl=1*tk5fep*_gcl_au*MTgxMTYxOTQ3NC4xNzc5MjE3NTkz*_ga*OTUyODM1NjgxLjE3NTQzMTk1MDM.*_ga_N56ERV2D97*czE3ODQ1NjYxNTUkbzMxMSRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.*_ga_PX1553NKMT*czE3ODQ1NjYxNTUkbzMwNyRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.\" style=\"color:#0891b2;font-weight:600;text-decoration:underline\">Solicitar Presupuesto<\/a> con ELICROM Per\u00fa.<\/p><\/div>\r\n\r\n<h2 id=\"caso-practico\" class=\"elicrom-h2\">Caso pr\u00e1ctico: termohigr\u00f3metro en almac\u00e9n farmac\u00e9utico (Lima)<\/h2>\r\n\r\n<p style=\"color:#1a1a1a;margin:0 0 16px\">Escenario ilustrativo de monitoreo ambiental 15\u201325 \u00b0C \/ 30\u201360 %HR:<\/p>\r\n\r\n<div class=\"elicrom-table-wrap\"><table class=\"elicrom-table-sm\"><thead><tr>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Par\u00e1metro<\/th>\r\n<th style=\"background:#0a2540;color:#fff;text-align:left;padding:14px;font-weight:600\">Detalle del ejemplo<\/th>\r\n<\/tr><\/thead><tbody>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;font-weight:600\">Instrumento<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Termohigr\u00f3metro port\u00e1til, resoluci\u00f3n 0,1 \u00b0C \/ 0,1 %HR<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc;font-weight:600\">Puntos<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;background:#f7fafc\">50 %HR y 75 %HR; 20 \u00b0C y 35 \u00b0C (dentro del alcance Lima)<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd;font-weight:600\">Resultado t\u00edpico<\/td><td style=\"padding:12px 14px;border-bottom:1px solid #b4c0cd\">Errores del orden de +1 %HR y +0,2 a +0,3 \u00b0C (ilustrativo)<\/td><\/tr>\r\n<tr><td style=\"padding:12px 14px;font-weight:600\">Acci\u00f3n del usuario<\/td><td style=\"padding:12px 14px\">Aplicar correcci\u00f3n o comparar con criterio de aceptaci\u00f3n interno<\/td><\/tr>\r\n<\/tbody><\/table><\/div>\r\n\r\n<p style=\"color:#475569;margin:0 0 26px;font-size:15px\"><em>Los n\u00fameros del ejemplo son did\u00e1cticos. Los puntos reales y la aceptaci\u00f3n se definen con el cliente y el alcance acreditado vigente.<\/em><\/p>\r\n\r\n<h2 id=\"faq\" class=\"elicrom-h2\">Preguntas frecuentes sobre termohigr\u00f3metros en Per\u00fa<\/h2>\r\n\r\n<p style=\"color:#475569;margin:0 0 16px;font-size:15px\">Toque cada pregunta para ver u ocultar la respuesta.<\/p>\r\n\r\n<div class=\"elicrom-faq\">\r\n<details>\r\n<summary>\u00bfCalibran medidores WBGT en Lima?<\/summary>\r\n<p class=\"faq-a\">S\u00ed. El alcance incluye medidores WBGT (bulbo h\u00famedo\/seco, globo y punto de roc\u00edo) dentro de los rangos publicados.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfCu\u00e1l es el rango de humedad acreditado?<\/summary>\r\n<p class=\"faq-a\">Cuatro tramos de 10 a 90 %HR, con CMC de 0,81 a 0,98 %HR seg\u00fan la tabla de Lima.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfY el rango de temperatura?<\/summary>\r\n<p class=\"faq-a\">De \u221220 a 60 \u00b0C en cinco tramos, con CMC de 0,11 a 0,44 \u00b0C.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfLos dataloggers usan la misma CMC?<\/summary>\r\n<p class=\"faq-a\">S\u00ed, comparten la matriz. Ver gu\u00eda de <a href=\"https:\/\/elicromperu.com\/calibracion-dataloggers-temperatura-humedad-lima-peru-alcance-acreditado\/\">dataloggers<\/a>.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfD\u00f3nde calibrar termohigr\u00f3metros en Per\u00fa?<\/summary>\r\n<p class=\"faq-a\">En ELICROM Per\u00fa, sede Lima, con certificados trazables ISO\/IEC 17025.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfCalibran fuera de 10\u201390 %HR?<\/summary>\r\n<p class=\"faq-a\">Indique el rango solicitado al cotizar para confirmar el alcance aplicable.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfIncluyen c\u00e1maras clim\u00e1ticas como unidad?<\/summary>\r\n<p class=\"faq-a\">Para c\u00e1maras clim\u00e1ticas como unidad, indique marca, modelo y rangos al cotizar; le confirmamos el alcance aplicable.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfQu\u00e9 m\u00e9todo usan?<\/summary>\r\n<p class=\"faq-a\">Comparaci\u00f3n en c\u00e1mara clim\u00e1tica (PEC.EL.HT) frente a termohigr\u00f3metro patr\u00f3n.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfEl certificado sirve para auditor\u00edas?<\/summary>\r\n<p class=\"faq-a\">Aporta evidencia t\u00e9cnica; la aceptaci\u00f3n depende de su sistema de calidad y del alcance acordado.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfCada cu\u00e1nto recalibrar?<\/summary>\r\n<p class=\"faq-a\">Lo define el usuario seg\u00fan riesgo, fabricante y requisitos de auditor\u00eda (a menudo anual).<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfAtienden fuera de Lima?<\/summary>\r\n<p class=\"faq-a\">Sede en Lima. La log\u00edstica de equipos o campo se coordina al cotizar.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfRelacionado con medios isotermos?<\/summary>\n<p class=\"faq-a\">S\u00ed, para cadena de fr\u00edo vea <a href=\"https:\/\/elicromperu.com\/calibracion-medios-isotermos-lima-peru-alcance-acreditado\/\">medios isotermos<\/a>.<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfY term\u00f3metros solo de temperatura?<\/summary>\r\n<p class=\"faq-a\">Consulte <a href=\"https:\/\/elicromperu.com\/calibracion-termometros-lima-peru-alcance-acreditado\/\">calibraci\u00f3n de term\u00f3metros<\/a> (bloques\/ba\u00f1os, ITS-90).<\/p>\r\n<\/details>\r\n<details>\r\n<summary>\u00bfC\u00f3mo solicito una cotizaci\u00f3n?<\/summary>\r\n<p class=\"faq-a\">Indique marca\/modelo, puntos de %HR\/\u00b0C y si es WBGT. <a href=\"https:\/\/servicio.elicrom.com\/servicio.cliente\/php\/cotizacion\/index.php?_gl=1*tk5fep*_gcl_au*MTgxMTYxOTQ3NC4xNzc5MjE3NTkz*_ga*OTUyODM1NjgxLjE3NTQzMTk1MDM.*_ga_N56ERV2D97*czE3ODQ1NjYxNTUkbzMxMSRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.*_ga_PX1553NKMT*czE3ODQ1NjYxNTUkbzMwNyRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.\">Solicitar Presupuesto<\/a>.<\/p>\r\n<\/details>\r\n<\/div>\r\n\r\n<div class=\"elicrom-cta-final\"><h2>\u00bfNecesita calibrar su termohigr\u00f3metro en Per\u00fa?<\/h2><p>ELICROM Per\u00fa calibra termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Lima con CMC publicadas (10\u201390 %HR; \u221220 a 60 \u00b0C) y certificados trazables ISO\/IEC 17025.<\/p><a class=\"elicrom-cta-btn\" href=\"https:\/\/servicio.elicrom.com\/servicio.cliente\/php\/cotizacion\/index.php?_gl=1*tk5fep*_gcl_au*MTgxMTYxOTQ3NC4xNzc5MjE3NTkz*_ga*OTUyODM1NjgxLjE3NTQzMTk1MDM.*_ga_N56ERV2D97*czE3ODQ1NjYxNTUkbzMxMSRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.*_ga_PX1553NKMT*czE3ODQ1NjYxNTUkbzMwNyRnMSR0MTc4NDU2ODA2MSRqNjAkbDAkaDA.\">Solicitar Presupuesto<\/a><\/div><\/div>","protected":false},"excerpt":{"rendered":"<p>Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).<\/p>","protected":false},"author":60250,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"om_disable_all_campaigns":false,"rs_blank_template":"","rs_page_bg_color":"","slide_template_v7":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[1677],"tags":[],"class_list":["post-83750","post","type-post","status-publish","format-standard","hentry","category-calibracion"],"acf":[],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO Pro 4.9.10 - aioseo.com -->\n\t<meta name=\"description\" content=\"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<meta name=\"author\" content=\"Domenica Zambrano\"\/>\n\t<meta name=\"google-site-verification\" content=\"mvH88JuvAdoXjW6tnuCHgNnYUWfgT6EpZmEhmfHzxx4\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/\" \/>\n\t<meta name=\"generator\" content=\"All in One SEO Pro (AIOSEO) 4.9.10\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"ELICROM - Especializados en actividades espec\u00edficas como son las \u00e1reas de Metrolog\u00eda, Medio Ambiente, Validaciones, Mantenimiento de Equipos de Laboratorio y Construcci\u00f3n\/Reformas de Laboratorios.\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM\" \/>\n\t\t<meta property=\"og:description\" content=\"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"131\" \/>\n\t\t<meta property=\"og:image:height\" content=\"77\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-07-31T16:45:59+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-07-31T17:02:52+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/ELICROMPERUSAC\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#blogposting\",\"name\":\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa - ELICROM\",\"headline\":\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa\",\"description\":\"Calibraci\\u00f3n acreditada de termohigr\\u00f3metros y WBGT en Lima. CMC 10\\u201390 %HR y \\u221220 a 60 \\u00b0C. Solicite presupuesto con ELICROM Per\\u00fa ISO\\\/IEC 17025.\",\"author\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#organization\"},\"publisher\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/termohigrometro-datalogger-ar.png\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#articleImage\"},\"datePublished\":\"2026-07-31T11:45:59-05:00\",\"dateModified\":\"2026-07-31T12:02:52-05:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#webpage\"},\"articleSection\":[\"Calibraci\\u00f3n\"],\"wordCount\":1534,\"about\":[{\"@type\":\"Thing\",\"name\":\"Calibraci\\u00f3n\"}],\"audience\":{\"@type\":\"Audience\",\"audienceType\":\"Profesionales de calidad, laboratorio y metrolog\\u00eda\"}},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/elicromperu.com\\\/en\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/category\\\/calibracion\\\/#listItem\",\"name\":\"Calibraci\\u00f3n\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/category\\\/calibracion\\\/#listItem\",\"position\":2,\"name\":\"Calibraci\\u00f3n\",\"item\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/category\\\/calibracion\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#listItem\",\"name\":\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#listItem\",\"position\":3,\"name\":\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/category\\\/calibracion\\\/#listItem\",\"name\":\"Calibraci\\u00f3n\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/author\\\/dzambrano\\\/#author\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/author\\\/dzambrano\\\/\",\"name\":\"Domenica Zambrano\",\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/59fbb1cdf816fa5eeaf6c3792fa166eb67c59c00fd55e582d399e747c8ee872f?s=96&d=mm&r=g\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#webpage\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/\",\"name\":\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa - ELICROM\",\"description\":\"Gu\\u00eda de calibraci\\u00f3n de termohigr\\u00f3metros port\\u00e1tiles y medidores WBGT en Per\\u00fa por ELICROM: humedad 10\\u201390 %HR y temperatura \\u221220 a 60 \\u00b0C, metodolog\\u00eda en c\\u00e1mara clim\\u00e1tica, trazabilidad ISO\\\/IEC 17025 y CMC de Lima (ene. 2026).\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/author\\\/dzambrano\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/author\\\/dzambrano\\\/#author\"},\"datePublished\":\"2026-07-31T11:45:59-05:00\",\"dateModified\":\"2026-07-31T12:02:52-05:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/\",\"name\":\"ELICROM\",\"alternateName\":\"ELICROM PERU S.A.C.\",\"description\":\"Especializados en actividades espec\\u00edficas como son las \\u00e1reas de Metrolog\\u00eda, Medio Ambiente, Validaciones, Mantenimiento de Equipos de Laboratorio y Construcci\\u00f3n\\\/Reformas de Laboratorios.\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#organization\"}},{\"@type\":[\"Organization\",\"LocalBusiness\"],\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/#organization\",\"name\":\"ELICROM\",\"description\":\"Elicrom Per\\u00fa es l\\u00edder en servicios especializados para la industria, destacando en calibraci\\u00f3n, ensayos y suministro de equipos de laboratorio y procesos\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/\",\"email\":\"comercioelectronico@elicrom.com\",\"telephone\":\"+51-1-766-9297\",\"foundingDate\":\"2018-01-01\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/elicromperu.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/logo-elicrom200X200.jpg\",\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#organizationLogo\",\"width\":200,\"height\":200,\"caption\":\"Elicrom logo\"},\"image\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/ELICROMPERUSAC\",\"https:\\\/\\\/www.instagram.com\\\/elicrom_peru\\\/\"],\"address\":{\"@type\":\"PostalAddress\",\"streetAddress\":\"Av. Faustino S\\u00e1nchez Carri\\u00f3n 615\",\"addressLocality\":\"Jes\\u00fas Mar\\u00eda\",\"addressRegion\":\"Lima\",\"postalCode\":\"15076\",\"addressCountry\":\"PE\"},\"currenciesAccepted\":\"PEN\",\"areaServed\":[{\"@type\":\"Country\",\"name\":\"PE\"},{\"@type\":\"AdministrativeArea\",\"name\":\"Lima\"}],\"knowsAbout\":[\"Calibraci\\u00f3n de termohigr\\u00f3metros en Lima: port\\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\\u00fa\",\"Calibraci\\u00f3n ISO IEC 17025 Per\\u00fa\",\"Servicio de Metrolog\\u00eda en Per\\u00fa\",\"Validaciones de Equipos en Per\\u00fa\",\"Mantenimiento de Equipos en Per\\u00fa\",\"Monitoreo ambiental\",\"Instrumentos de medici\\u00f3n\",\"Trazabilidad metrol\\u00f3gica\"],\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/elicromperu.com\\\/en\\\/calibracion-termohigrometros-lima-peru-alcance-acreditado\\\/#webpage\"},\"priceRange\":\"$$\"}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO Pro -->\r\n\t\t<title>Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM<\/title>\n\n","aioseo_head_json":{"title":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM","description":"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).","canonical_url":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"google-site-verification":"mvH88JuvAdoXjW6tnuCHgNnYUWfgT6EpZmEhmfHzxx4","miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#blogposting","name":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM","headline":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa","description":"Calibraci\u00f3n acreditada de termohigr\u00f3metros y WBGT en Lima. CMC 10\u201390 %HR y \u221220 a 60 \u00b0C. Solicite presupuesto con ELICROM Per\u00fa ISO\/IEC 17025.","author":{"@id":"https:\/\/elicromperu.com\/en\/#organization"},"publisher":{"@id":"https:\/\/elicromperu.com\/en\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/elicromperu.com\/wp-content\/uploads\/2026\/07\/termohigrometro-datalogger-ar.png","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#articleImage"},"datePublished":"2026-07-31T11:45:59-05:00","dateModified":"2026-07-31T12:02:52-05:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#webpage"},"isPartOf":{"@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#webpage"},"articleSection":["Calibraci\u00f3n"],"wordCount":1534,"about":[{"@type":"Thing","name":"Calibraci\u00f3n"}],"audience":{"@type":"Audience","audienceType":"Profesionales de calidad, laboratorio y metrolog\u00eda"}},{"@type":"BreadcrumbList","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en#listItem","position":1,"name":"Home","item":"https:\/\/elicromperu.com\/en","nextItem":{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en\/category\/calibracion\/#listItem","name":"Calibraci\u00f3n"}},{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en\/category\/calibracion\/#listItem","position":2,"name":"Calibraci\u00f3n","item":"https:\/\/elicromperu.com\/en\/category\/calibracion\/","nextItem":{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#listItem","name":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa"},"previousItem":{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#listItem","position":3,"name":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa","previousItem":{"@type":"ListItem","@id":"https:\/\/elicromperu.com\/en\/category\/calibracion\/#listItem","name":"Calibraci\u00f3n"}}]},{"@type":"Person","@id":"https:\/\/elicromperu.com\/en\/author\/dzambrano\/#author","url":"https:\/\/elicromperu.com\/en\/author\/dzambrano\/","name":"Domenica Zambrano","image":{"@type":"ImageObject","url":"https:\/\/secure.gravatar.com\/avatar\/59fbb1cdf816fa5eeaf6c3792fa166eb67c59c00fd55e582d399e747c8ee872f?s=96&d=mm&r=g"}},{"@type":"WebPage","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#webpage","url":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/","name":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM","description":"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/elicromperu.com\/en\/#website"},"breadcrumb":{"@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#breadcrumblist"},"author":{"@id":"https:\/\/elicromperu.com\/en\/author\/dzambrano\/#author"},"creator":{"@id":"https:\/\/elicromperu.com\/en\/author\/dzambrano\/#author"},"datePublished":"2026-07-31T11:45:59-05:00","dateModified":"2026-07-31T12:02:52-05:00"},{"@type":"WebSite","@id":"https:\/\/elicromperu.com\/en\/#website","url":"https:\/\/elicromperu.com\/en\/","name":"ELICROM","alternateName":"ELICROM PERU S.A.C.","description":"Especializados en actividades espec\u00edficas como son las \u00e1reas de Metrolog\u00eda, Medio Ambiente, Validaciones, Mantenimiento de Equipos de Laboratorio y Construcci\u00f3n\/Reformas de Laboratorios.","inLanguage":"en-US","publisher":{"@id":"https:\/\/elicromperu.com\/en\/#organization"}},{"@type":["Organization","LocalBusiness"],"@id":"https:\/\/elicromperu.com\/en\/#organization","name":"ELICROM","description":"Elicrom Per\u00fa es l\u00edder en servicios especializados para la industria, destacando en calibraci\u00f3n, ensayos y suministro de equipos de laboratorio y procesos","url":"https:\/\/elicromperu.com\/en\/","email":"comercioelectronico@elicrom.com","telephone":"+51-1-766-9297","foundingDate":"2018-01-01","logo":{"@type":"ImageObject","url":"https:\/\/elicromperu.com\/wp-content\/uploads\/2026\/06\/logo-elicrom200X200.jpg","@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#organizationLogo","width":200,"height":200,"caption":"Elicrom logo"},"image":{"@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/ELICROMPERUSAC","https:\/\/www.instagram.com\/elicrom_peru\/"],"address":{"@type":"PostalAddress","streetAddress":"Av. Faustino S\u00e1nchez Carri\u00f3n 615","addressLocality":"Jes\u00fas Mar\u00eda","addressRegion":"Lima","postalCode":"15076","addressCountry":"PE"},"currenciesAccepted":"PEN","areaServed":[{"@type":"Country","name":"PE"},{"@type":"AdministrativeArea","name":"Lima"}],"knowsAbout":["Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa","Calibraci\u00f3n ISO IEC 17025 Per\u00fa","Servicio de Metrolog\u00eda en Per\u00fa","Validaciones de Equipos en Per\u00fa","Mantenimiento de Equipos en Per\u00fa","Monitoreo ambiental","Instrumentos de medici\u00f3n","Trazabilidad metrol\u00f3gica"],"mainEntityOfPage":{"@id":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/#webpage"},"priceRange":"$$"}]},"og:locale":"en_US","og:site_name":"ELICROM - Especializados en actividades espec\u00edficas como son las \u00e1reas de Metrolog\u00eda, Medio Ambiente, Validaciones, Mantenimiento de Equipos de Laboratorio y Construcci\u00f3n\/Reformas de Laboratorios.","og:type":"article","og:title":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM","og:description":"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).","og:url":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/","og:image":"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg","og:image:secure_url":"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg","og:image:width":131,"og:image:height":77,"article:published_time":"2026-07-31T16:45:59+00:00","article:modified_time":"2026-07-31T17:02:52+00:00","article:publisher":"https:\/\/www.facebook.com\/ELICROMPERUSAC","twitter:card":"summary_large_image","twitter:title":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa - ELICROM","twitter:description":"Gu\u00eda de calibraci\u00f3n de termohigr\u00f3metros port\u00e1tiles y medidores WBGT en Per\u00fa por ELICROM: humedad 10\u201390 %HR y temperatura \u221220 a 60 \u00b0C, metodolog\u00eda en c\u00e1mara clim\u00e1tica, trazabilidad ISO\/IEC 17025 y CMC de Lima (ene. 2026).","twitter:image":"https:\/\/elicromperu.com\/wp-content\/uploads\/2021\/12\/cropped-Logo-Elicrom-Azul.jpg"},"aioseo_meta_data":{"post_id":"83750","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_url":null,"og_image_width":null,"og_image_height":null,"og_image_custom_url":null,"og_image_custom_fields":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":false,"twitter_card":"default","twitter_image_type":"default","twitter_image_url":null,"twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_title":null,"twitter_description":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"schema_type":"default","schema_type_options":null,"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"seo_analyzer_scan_date":"2026-07-31 17:03:54","breadcrumb_settings":null,"limit_modified_date":false,"open_ai":null,"ai":null,"created":"2026-07-31 16:45:59","updated":"2026-07-31 17:05:56","reviewed_by":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/elicromperu.com\/en\" title=\"Home\">Home<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\t<a href=\"https:\/\/elicromperu.com\/en\/category\/calibracion\/\" title=\"Calibraci\u00f3n\">Calibraci\u00f3n<\/a>\n<\/span><span class=\"aioseo-breadcrumb-separator\">&raquo;<\/span><span class=\"aioseo-breadcrumb\">\n\tCalibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa\n<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/elicromperu.com\/en"},{"label":"Calibraci\u00f3n","link":"https:\/\/elicromperu.com\/en\/category\/calibracion\/"},{"label":"Calibraci\u00f3n de termohigr\u00f3metros en Lima: port\u00e1tiles, WBGT y alcance acreditado | ELICROM Per\u00fa","link":"https:\/\/elicromperu.com\/en\/calibracion-termohigrometros-lima-peru-alcance-acreditado\/"}],"_links":{"self":[{"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/posts\/83750","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/users\/60250"}],"replies":[{"embeddable":true,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/comments?post=83750"}],"version-history":[{"count":5,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/posts\/83750\/revisions"}],"predecessor-version":[{"id":83765,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/posts\/83750\/revisions\/83765"}],"wp:attachment":[{"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/media?parent=83750"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/categories?post=83750"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/elicromperu.com\/en\/wp-json\/wp\/v2\/tags?post=83750"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}